Orange light or beeping
The orange TROUBLE light and 3 beeps once a minute mean the panel has found a fault. It is not an alarm. The display shows TRBL next to READY or NOT READY.
- See what the fault is. Press i / OK on the panel again and again. Each press shows the next message, for example
Z09 LOW BATTERY,AC FAILUREorCOMM. FAILURE. Write down what it says. - Stop the beeps. Press OFF (disarm) and enter your own user code, even though the alarm is already off. This stops the trouble beeps for 4 hours. The orange light stays on until the fault is fixed.
- Check the simple things using the list below. The orange light goes out by itself once the cause is fixed.
How to check trouble messages on your Visonic PowerMaster 10 / 30
Read the transcript
- Welcome to Tyger Security. Here’s how to check a trouble message on your Visonic PowerMaster 10 or 30.
- Spot the warning. If the orange trouble light is on, and the panel beeps three times a minute, the display flashes
TRBL. After an alarm, it showsMEMORY. - Press OK. Press the OK button (marked i / OK). The panel name is shown first.
- Keep pressing OK to see each message in turn, such as zone nine, low battery, in the kitchen (
Z09 LOW BATTERY), a missing device (Z15 MISSING), or a communication failure (COMM. FAILURE). Alarm memory is shown first, then troubles. - Common messages: LOW BATTERY – a device battery is running low. MISSING – a device hasn’t reported to the panel. TAMPER OPEN – a device’s tamper is open. AC FAILURE – no power supplied to the device. COMM. FAILURE – a message couldn’t be sent.
- Back to READY. After the last message, the display returns to READY. The trouble light clears once the fault is fixed. MEMORY clears the next time you set the alarm.
- Top tip: to silence the trouble beeps for four hours, disarm the system again, even though it’s already disarmed.
- Not sure what a message means? Call Tyger Security on 07877 633633, or visit our support page.
What the message means
- AC FAILURE
- No mains power to the panel. Check the plug or fused spur is on, and whether there is a power cut. It clears when power is back.
- CPU LOW BATTERY
- The panel’s backup battery is low. This is normal for a few hours after a power cut. If it is still there a few hours after the power is back on, book a visit. Please don’t open the panel.
- LOW BATTERY (with a zone, e.g. Z09)
- A detector, keyfob or siren battery is running out. Note the zone number and name, and book a visit within 7 days.
- TAMPER OPEN
- A detector cover is open or a device has been knocked off the wall. Check the named device. If the panel says CPU TAMPER OPEN, or it won’t clear, book a visit.
- MISSING
- A device hasn’t checked in for a while, often because of a flat battery. Book a visit.
- COMM. FAILURE, LINE FAILURE or GSM NET FAIL
- The alarm couldn’t send a message. Check the phone line or router hasn’t been unplugged or changed. If it carries on, see My phone isn’t working or book a visit.
- CLEAN ME
- A smoke detector needs cleaning or checking. Book a visit.
Display says MEMORY? That means an alarm or tamper happened while it was set. Press i / OK to see which zone. It clears the next time you set the alarm.
Still showing after these checks? Book a visit. We never give out engineer or installer codes. If a fix needs the engineer menu, one of our engineers will come out.